Fluke 115 Field Service Test Multimeter
ME3115
$289.00
QTY | Price |
---|---|
1 | $289.00 |
Description
Designed by electricians and engineered by Fluke, the Fluke 115 is a compact true-RMS meter ideal for field service technicians. This versatile tool is perfect for a wide range of electrical and electronic testing applications, offering reliable performance and accuracy in a user-friendly design.
Safety conformance:
All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÜV listed and VDE.
Features
- Large white LED backlight to work in poorly lit areas
- Resistance and continuity
- Min/Max/Average to record signal fluctuations
- CAT III 600 V safety rated
Specifications
Maximum voltage between any terminaland earth ground
600 V
Surge protection
6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Display
Digital: 6,000 counts, updates 4 per second
Bar graph
33 segments, updates 32 per second
Operating Temperature
-10 °C to 50 °C
Storage Temperature
-40 °C to 60 °C
Battery type
9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
400 hours typical, without backlight
Accuracy Specifications
DC millivolts
Range: 600.0 mV | Resolution: 0.1 mV | Accuracy: ± ([% of reading] [counts]): 0.5% 2
DC volts
Range/Resolution: 6.000 V / 0.001 V | Range/Resolution: 60.00 V / 0.01 V | Range/Resolution: 600.00 V / 0.1 V | Accuracy: ± ([% of reading] [counts]): 0.5% 2
AC millivolts1 true-rms
Range: 600.0 mV | Resolution: 0.1 mV | Accuracy: 1.0 % 3 (dc, 45 Hz to 500 Hz)2.0 % 3(500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution: 6.000 V / 0.001 V | Range/Resolution: 60.00 V / 0.01 V | Range/Resolution: 600.0 V / 0.1 V | Accuracy: 1.0 % 3 (dc, 45 Hz to 500 Hz)2.0 % 3(500 Hz to 1 kHz)
Continuity
Range: 600 Ω | Resolution: 1 Ω | Accuracy: Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer.
Ohms
Range/Resolution: 600.0 Ω / 0.1 Ω | Range/Resolution: 6.000 kΩ / 0.001 kΩ | Range/Resolution: 60.00 kΩ / 0.01 kΩ | Range/Resolution: 600.0 kΩ / 0.1 kΩ | Range/Resolution: 6.000 MΩ / 0.001 MΩ | Accuracy: 0.9 % 1 | Range/Resolution: 40.00 MΩ / 0.01 MΩ | Accuracy: 1.5 % 2
Diode Test
Range/Resolution: 2.00 V / 0.001 V | Accuracy: 0.9% 2
Capacitance
Range/Resolution: 1000 nF / 1 nF | Range/Resolution: 10.00 µF / 0.01 µF | Range/Resolution: 100.0 µF / 0.1 µF | Range/Resolution: 9999 µF / 1 µF | Range/Resolution: 100 µF to 1000 µF | Accuracy: 1.9% 2 | Range/Resolution: > 1000 µF | Accuracy: 5% 20%
Lo-Z Capacitance
Range: 1 nF to 500 µF | Accuracy: 10% 2 typical
AC amps true-rms (45 Hz to 500Hz)
Range/Resolution: 6.000 A / 0.001 A | Range/Resolution: 10.00 A / 0.01 A | Accuracy: 1.5% 3, 20 A overload for 30-seconds max
DC amps
Range/Resolution: 6.000 A / 0.001 A | Range/Resolution: 10.00 A / 0.01 A | Accuracy: 1.0% 3, 20 A overload for 30-seconds max
Hz (V or A input)2
Range/Resolution: 99.99 Hz / 0.01 Hz | Range/Resolution: 999.9 Hz / 0.01 Hz | Range/Resolution: 9.999 kHz / 0.001 kHz | Range/Resolution: 50 kHz / 0.01 kHz | Accuracy: 0.1% 2
You Might Also Like
All prices are in Australian Dollars and include GST. GST will be removed from your order if you are ordering from outside Australia.
Products may differ from pictured.
All trademarks and trade names are the properties of their respective owners. Wiltronics disclaims any proprietary interest in trademarks and trade names other than its own.